Skip to product information
1 of 1

3BSE037760R1 | ABB TB840A Modulebus Cluster Modem

3BSE037760R1 | ABB TB840A Modulebus Cluster Modem

  • Manufacturer: ABB

  • Product No.: TB840A

  • Condition:1000 in stock

  • Product Type: Modulebus Cluster Modem

  • Product Origin: Sweden

  • Payment: T/T, Western Union

  • Weight: 200g

  • Shipping port: Xiamen

  • Warranty: 12 months

  • 24/7 Support
  • 30-Day Returns
  • Fast Shipping

ABB TB840/TB840A ModuleBus Modem

The TB840 and TB840A are advanced ModuleBus Modems that enable communication between S800 I/O systems and parent controllers or PLCs via industry-standard field buses. These devices provide both fiber optic and electrical ModuleBus interfaces, ensuring scalable and reliable distributed I/O connectivity.


Key Features and Benefits

  • Dual Fiber Optic Ports:

    • Connects to the optical ModuleBus for extended I/O cluster distribution.
  • Electrical ModuleBus Connection:

    • Supports up to 12 I/O modules per bus.
  • Redundancy Support:

    • TB840A is optimized for redundancy by linking separate optical ModuleBus lines to the same electrical ModuleBus.
  • Supervisory Functions:

    • Monitors I/O ModuleBus and power supply status.
  • Isolated Power Supply:

    • Protects I/O modules through isolation.
  • Hot Swapping:

    • Enables easy replacement without system downtime.

Technical Specifications

Attribute Details
Article Number 3BSE037760R1
Communication Protocol ModuleBus
Redundancy - Line: Yes
yaml
| - Module: Yes |

| Power Consumption | 24 V (typ. 120 mA) |
| Hot Swap | Yes |
| Compatibility | Used with HI Controllers |


Environmental and Certification Details

Attribute Details
Operating Temperature 0 to +55 °C (+32 to +131 °F)
Storage Temperature -40 to +70 °C (-40 to +158 °F)
Relative Humidity 5–95% (non-condensing)
Corrosion Protection ISA-S71.04: G3
Pollution Degree Degree 2 (IEC 60664-1)
Ingress Protection IP20 (EN 60529)
Compliance - CE Marking

| - RoHS (Directive 2011/65/EU) | - WEEE (Directive 2012/19/EU) |

| Hazardous Location Approvals | - C1 Div 2 cULus
| - C1 Zone 2 cULus
| - ATEX Zone 2 |
| Marine Certifications | ABS, BV, DNV-GL, LR |


Mechanical Details

Attribute Value
Width 54 mm (2.13 in.)
Height 119 mm (4.69 in.)
Depth 96 mm (3.78 in.)
Weight 0.2 kg (0.44 lbs.)

Applications and Use Cases

The TB840/TB840A is designed for:

  • Local I/O Cluster Distribution:

    • Ideal for situations requiring more than 12 I/O modules in an I/O station.
  • Redundancy Configurations:

    • Ensures seamless operation with redundant I/O systems using TB840A.
  • Industrial Automation:

    • Compatible with S800 I/O systems and various HI controllers.

Ordering Information

For more details or purchasing inquiries, visit ABB’s official website or contact authorized distributors.

 

 

Check below popular items for more information in  Industrial Control Hub
Brand Description  Price (USD)  Stock Link
ABB DSBC174 Bus Extender S100 I/O Bus 1000–2000 790 DSBC174 Bus Extender
ABB 5SDF0345D0006 Diode Pressp 0–700 870 5SDF0345D0006 Diode
ABB PP835A Operator Panel 2786–3786 210 PP835A Operator Panel
ABB UFC718AE101 Main Circuit Interface Board 1857–2857 530 UFC718AE101 Interface Board
ABB PM866K01 Processor Unit Kit 8786–9786 450 PM866K01 Processor Unit
ABB PFTL101A-1.0KN Load Cell 8786–9786 300 PFTL101A-1.0KN Load Cell
ABB CI820V1 Communication Module 286–1286 210 CI820V1 Communication Module
View full details

Product Description

ABB TB840/TB840A ModuleBus Modem

The TB840 and TB840A are advanced ModuleBus Modems that enable communication between S800 I/O systems and parent controllers or PLCs via industry-standard field buses. These devices provide both fiber optic and electrical ModuleBus interfaces, ensuring scalable and reliable distributed I/O connectivity.


Key Features and Benefits

  • Dual Fiber Optic Ports:

    • Connects to the optical ModuleBus for extended I/O cluster distribution.
  • Electrical ModuleBus Connection:

    • Supports up to 12 I/O modules per bus.
  • Redundancy Support:

    • TB840A is optimized for redundancy by linking separate optical ModuleBus lines to the same electrical ModuleBus.
  • Supervisory Functions:

    • Monitors I/O ModuleBus and power supply status.
  • Isolated Power Supply:

    • Protects I/O modules through isolation.
  • Hot Swapping:

    • Enables easy replacement without system downtime.

Technical Specifications

Attribute Details
Article Number 3BSE037760R1
Communication Protocol ModuleBus
Redundancy - Line: Yes
yaml
| - Module: Yes |

| Power Consumption | 24 V (typ. 120 mA) |
| Hot Swap | Yes |
| Compatibility | Used with HI Controllers |


Environmental and Certification Details

Attribute Details
Operating Temperature 0 to +55 °C (+32 to +131 °F)
Storage Temperature -40 to +70 °C (-40 to +158 °F)
Relative Humidity 5–95% (non-condensing)
Corrosion Protection ISA-S71.04: G3
Pollution Degree Degree 2 (IEC 60664-1)
Ingress Protection IP20 (EN 60529)
Compliance - CE Marking

| - RoHS (Directive 2011/65/EU) | - WEEE (Directive 2012/19/EU) |

| Hazardous Location Approvals | - C1 Div 2 cULus
| - C1 Zone 2 cULus
| - ATEX Zone 2 |
| Marine Certifications | ABS, BV, DNV-GL, LR |


Mechanical Details

Attribute Value
Width 54 mm (2.13 in.)
Height 119 mm (4.69 in.)
Depth 96 mm (3.78 in.)
Weight 0.2 kg (0.44 lbs.)

Applications and Use Cases

The TB840/TB840A is designed for:

  • Local I/O Cluster Distribution:

    • Ideal for situations requiring more than 12 I/O modules in an I/O station.
  • Redundancy Configurations:

    • Ensures seamless operation with redundant I/O systems using TB840A.
  • Industrial Automation:

    • Compatible with S800 I/O systems and various HI controllers.

Ordering Information

For more details or purchasing inquiries, visit ABB’s official website or contact authorized distributors.

 

 

Check below popular items for more information in  Industrial Control Hub
Brand Description  Price (USD)  Stock Link
ABB DSBC174 Bus Extender S100 I/O Bus 1000–2000 790 DSBC174 Bus Extender
ABB 5SDF0345D0006 Diode Pressp 0–700 870 5SDF0345D0006 Diode
ABB PP835A Operator Panel 2786–3786 210 PP835A Operator Panel
ABB UFC718AE101 Main Circuit Interface Board 1857–2857 530 UFC718AE101 Interface Board
ABB PM866K01 Processor Unit Kit 8786–9786 450 PM866K01 Processor Unit
ABB PFTL101A-1.0KN Load Cell 8786–9786 300 PFTL101A-1.0KN Load Cell
ABB CI820V1 Communication Module 286–1286 210 CI820V1 Communication Module