Mahsulot ma'lumotlariga o'tish
1 ning 1

Emerson KJ2201X1-HA1 DeltaV SIS Simplex SLS Terminal Bloki

Emerson KJ2201X1-HA1 DeltaV SIS Simplex SLS Terminal Bloki

  • Manufacturer: Emerson

  • Product No.: KJ22011X1-HA1

  • Condition:1000 zaxirada mavjud

  • Product Type: DeltaV Xavfsizlik Tizimi

  • Product Origin: 8962993258755

  • Payment: T/T, Western Union

  • Weight: 250g

  • Shipping port: Xiamen

  • Warranty: 12 months

  • 24/7 Qo'llab-quvvatlash
  • 30 kun ichida qaytarish
  • Tez yetkazib berish

Emerson KJ2201X1-HA1 DeltaV SIS Simplex SLS Terminal Block - Xavfsizlik tizimlari uchun ichki xavfsiz maydon interfeysi

Emerson KJ2201X1-HA1 (12P3322X022) DeltaV SIS Simplex SLS Terminal Block xavfsizlik asbob-uskunalar tizimlarida KJ2201X1-BA1 Smart Logic Solver (SLS 1508) uchun ichki xavfsiz maydon simlarini ulashni ta'minlaydi. Xavfli hududlarga o'rnatish uchun mo'ljallangan ushbu terminal bloki xavfsizlik jihatdan muhim maydon qurilmalari bilan DeltaV SIS boshqaruvchisi o'rtasida ishonchli ulanishlarni ta'minlaydi, neft va gaz, kimyo, farmatsevtika va elektr energiyasi ishlab chiqarish korxonalarida SIL 2/3 sertifikatlangan xavfsizlik himoyasini talab qiluvchi 16 ta sozlanadigan I/O kanallarini qo'llab-quvvatlaydi.

Asosiy Texnik Xususiyatlar

  • Model raqami: KJ2201X1-HA1 (Alternativ: 12P3322X022)
  • Konfiguratsiya: Ichki xavfsiz doiralar uchun Simplex SLS terminal bloki
  • Moslik: KJ2201X1-BA1 Smart Logic Solver (SLS 1508)
  • I/O kanallari: 16 sozlanadigan kanal (DI/DO/AI HART/HART ikki holatli chiqish)
  • Joriy reytinglari: 30mA (terminal A-B), 1A (terminal A-C)
  • Ishlash harorati: -40°C dan +70°C gacha (-40°F dan 158°F gacha)
  • Saqlash harorati: -40°C dan +85°C gacha (-40°F dan 185°F gacha)
  • Himoya darajasi: O'rnatilganda IP20
  • O'rnatish: 8 kenglikdagi SIS tashuvchi ustida T-turi DIN relsi
  • Og'irligi: Taxminan 0.25 kg (0.55 lbs)

Global Xavfsizlik Sertifikatlari

Dunyo bo'ylab xavfsizlik asbob-uskunalari tizimlari va xavfli hududlarda qo'llash uchun sertifikatlangan:

  • ATEX Europe: II 3 G sertifikatlangan Zona 2 portlovchi atmosfera o'rnatmalari uchun (Nemko No. 02ATEX431U)
  • IECEx International: Xavfli joylar uchun global ichki xavfsizlik standartlariga muvofiq
  • FM/CSA Shimoliy Amerika: I sinf, 2-bo‘lim, A-D guruhlar o‘rnatishlari uchun sertifikatlangan
  • CE belgisi: Xavfsizlik va EMC direktivalari uchun Yevropa muvofiqligi
  • SIL sertifikati: Sertifikatlangan SLS bilan birga ishlatilganda SIL 2/3 xavfsizlik yaxlitligi darajasi ilovalarini qo‘llab-quvvatlaydi

Xavfsizlik Instrumentatsiyalangan Tizim Ilovalari

Favqulodda o‘chirish (ESD) tizimlari: Xavfsizlik uchun muhim o‘chirish klapanlari, favqulodda bosimni tushirish tizimlari va yong‘in hamda gaz aniqlash qurilmalarini Smart Logic Solver bilan interfeys qiling. Ichki xavfsiz dizayn portlovchi muhitni yoqolmaydigan minimal energiyali zanjirlarni ta’minlaydi, bu esa yonuvchan gazlar yoki bug‘lar mavjud bo‘lishi mumkin bo‘lgan dengiz platformalari, neftni qayta ishlash zavodlari va kimyo korxonalari uchun juda muhimdir.

Yoqilg‘i boshqaruv tizimlari (BMS): Olov detektorlari, yoqilg‘i klapan pozitsiyasi kalitlari va havo oqimi sensorlarini qozon va pech ishlarini boshqaruvchi xavfsizlik mantiqiy boshqaruvchilarga ulang. Terminal blokining 16 ta sozlanadigan I/O kanallari turli sensor turlarini, jumladan diskret kalitlar, HART qo‘llab-quvvatlangan uzatuvchilar va klapan boshqaruvi uchun ikki holatli chiqishlarni qo‘llab-quvvatlaydi, bu esa keng qamrovli yoqilg‘i xavfsizligini monitoring qilish imkonini beradi.

Yuoqori ishonchlilikdagi bosimdan himoya (HIPPS): Quvurlar bosimidan ortiqcha himoya tizimlarida ultra tez o‘chirish klapanlari va bosim uzatuvchilarini interfeys qiling. Ichki xavfsiz zanjirlar uchun 30mA tok reytingi (A-B terminallari) energiya cheklov talablariga muvofiqlikni ta’minlaydi, 1A reytingi (A-C terminallari) esa ichki xavfsizlik talab qilinmaganida yuqori quvvatli maydon qurilmalarini qo‘llab-quvvatlaydi.

Xavfsizlik o‘zaro bloklash tizimlari: Xavfli uskunalar kombinatsiyalarini yoki xavfsiz bo‘lmagan ish sharoitlarini oldini olish uchun jarayon xavfsizligi o‘zaro bloklashlarini amalga oshiring. Ruxsat beruvchi kalitlar, pozitsiya sensorlari va xavfsizlik rele chiqishlarini ulab, ishga tushirish ketma-ketligini ta’minlang, teskari aylanishni oldini oling va yuqori quvvatli uskunalarni yoqishdan oldin to‘g‘ri moslashuvni ta’minlang.

Yong‘in va gazni aniqlash: Yonuvchi gaz detektorlarini, zaharli gaz monitoringlarini va olov detektorlarini xavfsizlik o‘chirish mantiqiga integratsiya qiling. HART aloqa imkoniyati aqlli maydon qurilmalaridan ilg‘or diagnostika va ko‘p o‘zgaruvchan ma’lumotlarni taqdim etadi, bu esa sensorning eskirishi yoki kalibrlash siljishi xavfsizlik tizimi ishonchliligiga ta’sir qilishi mumkinligini erta ogohlantiradi.

Ichki xavfsiz dizayn afzalliklari

Xavfli hudud xavfsizlik tizimlarini o‘rnatishda muhim afzalliklar:

  • Energiya cheklovi: Elektr zanjirlari portlovchi muhitni yoqolmaydigan minimal elektr energiyasini hosil qiladi
  • O‘rnatishni soddalashtirish: Zona 2/Bo‘lim 2 hududlarida portlashga chidamli quvurlar yoki birikma qutilari kerak emas
  • O‘rnatish xarajatlarini kamaytirish: Ichki xavfsiz simlash qimmatbaho xavfli hudud qoplamalarini yo‘q qiladi
  • Yaxshilangan xavfsizlik: Yagona nuqtali nosozliklar bilan buzib bo‘lmaydigan passiv himoya
  • Texnik xizmat ko‘rsatish imkoniyati: Ko‘plab yurisdiktsiyalarda maydon qurilmalari issiq ish ruxsatnomalarisiz xizmat ko‘rsatish mumkin

Sozlanadigan I/O kanal imkoniyatlari

Moslashuvchan signal turlari turli xavfsizlik maydon qurilmalari talablarini qo'llab-quvvatlaydi:

Diskret kirish (DI): Xavfsizlik kalitlari holatlari, klapan chegarasi kalitlari, bosim kaliti kontaktlari va favqulodda to'xtatish tugmasi holatlarini kuzatib boring. Diskret kirishlar ochiq sxemalar xavfsiz sharoitlarni, yopiq sxemalar esa normal ishlash yoki signal holatlarini bildiradigan ishonchli monitoringni ta'minlaydi.

Diskret chiqish (DO): Xavfsizlik o'chirish klapanlari, signalizatsiya qurilmalari va ruxsat beruvchi rele bobinlarini boshqaring. Diskret chiqishlar quvvat yoki boshqaruv signali yo'qolganda maydon qurilmalarini avtomatik xavfsiz holatga o'tkazadigan de-energize-to-trip mantiqini amalga oshiradi.

Analog kirish HART: Aqlli bosim uzatkichlari, harorat sensorlari va oqim o'lchagichlarni HART raqamli aloqa bilan interfeys qiling. Asosiy jarayon o'zgaruvchilariga qo'shimcha o'lchovlar, qurilma diagnostikasi va sozlash parametrlariga HART protokoli orqali kirish, oldindan texnik xizmat ko'rsatish va ilg'or xavfsizlik mantiqini ta'minlaydi.

HART ikki holatli chiqish: HART qo'llab-quvvatlanadigan aqlli pozitsionerlar va yakuniy boshqaruv elementlarini boshqaring. Discret yoqish/o‘chirish boshqaruvini HART aloqa bilan birlashtirib, xavfsizlik o'chirish ilovalarida klapan pozitsiyasi fikr-mulohazasi, diagnostika ma'lumotlari va masofadan sozlash imkoniyatlarini taqdim etadi.

O‘rnatish talablari va eng yaxshi amaliyotlar

Ishonchli xavfsizlik tizimi ishlashi uchun muhim ko'rsatmalar:

DIN rayga o'rnatish: KJ2201X1-BA1 Smart Logic Solver bilan birga 8 kenglikdagi SIS tashuvchisidagi T-turi DIN rayga o'rnating. Terminal bloki va SLS moduli o'rtasida to'g'ri mexanik ushlash va elektr aloqasini ta'minlang. Tizimni yoqishdan oldin terminal blokining to'liq joylashganligini tekshiring, bu oraliq ulanishlarning oldini oladi.

O'z-o'zidan xavfsizlik to'siqlari: O'z-o'zidan xavfsiz bo'lmagan maydon qurilmalarini ulashda terminal blok va maydon simlari orasida sertifikatlangan o'z-o'zidan xavfsizlik to'siqlarini o'rnating. To'siqlar to'g'ri yerga ulangan va o'z-o'zidan xavfsizlik yaxlitligini saqlash uchun maxsus xavfli hudud tasnifiga mos bo'lishi kerak.

Sim o'lchami va yo'nalishi: Joriy reytinglar va kuchlanish tushishini hisoblash uchun mos sim o'lchamlaridan foydalaning. Energiya cheklovini buzishi mumkin bo'lgan induktsiyalangan kuchlanishlarni oldini olish uchun o'z-o'zidan xavfsiz simlarni o'z-o'zidan xavfsiz bo'lmagan sxemalardan alohida yo'naltiring. ATEX/IECEx o'rnatish talablariga muvofiq minimal ajratish masofalarini saqlang.

Yerga ulash va ekranlash: Terminal blok yerini xavfsizlik tizimi yer avtobusiga ulang. HART aloqa sxemalari uchun maydon qurilmasidan terminal blokgacha ekran uzluksizligini saqlang. Noto'g'ri yerga ulash analog o'lchovlarga yoki HART aloqa ishonchliligiga ta'sir qiluvchi umumiy rejim shovqinini keltirib chiqarishi mumkin.

Atrof-muhit xususiyatlari

Parametr Texnik xususiyatlar
Ishlash harorati -40°C dan +70°C gacha (-40°F dan 158°F gacha)
Saqlash harorati -40°C dan +85°C gacha (-40°F dan 185°F gacha)
Namlik Oralig‘i 5% dan 95% gacha kondensatsiyasiz
Havodagi ifloslantiruvchi moddalar ISA-S71.04-1985 G3 sinfi, konformal qoplama bilan
IP reytingi Shkafga o'rnatilganda IP20

Nima uchun Industrial Control Hub ni tanlash kerak?

Sizning haqiqiy Emerson DeltaV SIS xavfsizlik komponentlari uchun ixtisoslashgan manbaingiz:

  • ✓ To'liq ishlab chiqaruvchi izchilligi va xavfsizlik sertifikatlari bilan 100% haqiqiy OEM mahsulotlari
  • ✓ Sertifikatlangan funksional xavfsizlik muhandislari tomonidan ekspert SIS texnik qo'llab-quvvatlash
  • ✓ Hozirgi ishlab chiqarish va eski DeltaV SIS komponentlarining keng inventariyasi
  • ✓ AQSh, Buyuk Britaniya, Yevropa Ittifoqi va Osiyo-Tinch okeani bozorlariga tezkor global yetkazib berish
  • ✓ Xavfsizlik tizimi loyihalari uchun hajm chegirmalari bilan raqobatbardosh narxlar
  • ✓ Xavfsizlik qo‘llanmalari va sertifikat hujjatlarini o‘z ichiga olgan to‘liq hujjatlar

Qo‘shimcha DeltaV SIS komponentlari

Mahsulot Modeli Tavsif Havola
KJ2201X1-BA1 Logic Solver SLS 1508 Xavfsizlik boshqaruvchisi - ushbu terminal blok ulanuvchi Smart Logic Solver Mahsulotni Ko'rish
KL1604X1-BA1 Xavfsizlik tizimlarida tarmoq ulanishi uchun Xavfsizlik izolyatsiya porti (Mis) Mahsulotni Ko'rish
VE4050S2K1C0 DeltaV 8 kenglikdagi Logic Solver gorizontal ko‘taruvchi SLS va terminal bloklarini o‘rnatish uchun Mahsulotni Ko'rish

Buyurtma ma'lumotlari va tizim rejalashtirish

  • KJ2201X1-HA1 (12P3322X022): DeltaV SIS Simplex SLS Terminal Bloki (ushbu mahsulot)
  • Talab qilinadigan komponent: KJ2201X1-BA1 Smart Logic Solver (SLS 1508) - alohida sotiladi
  • Ko‘taruvchi talab qilinadi: T-turi DIN relsli 8 kenglikdagi SIS ko‘taruvchi
  • Tizim mosligi: To‘liq funksionallik uchun DeltaV v10.3 yoki undan keyingi versiyasi
  • Zaxira qismlar strategiyasi: Muhim xavfsizlik tizimlari uchun zaxira terminal bloklarini saqlang, shunda ish to‘xtashi kamayadi

Texnik Hujjatlar & Qo'llab-quvvatlash

To‘liq xavfsizlik qo‘llanmalari, o‘rnatish ko‘rsatmalari, ATEX/IECEx sertifikatlari va SIL sertifikat hujjatlari so‘rov bo‘yicha mavjud. Bizning funksional xavfsizlik muhandisligi jamoamiz murakkab DeltaV SIS loyihalari uchun tizim arxitekturasi bo‘yicha maslahat, ichki xavfsizlik hisob-kitoblari, xavfli hududlarni tasniflash bo‘yicha ko‘rsatmalar va xavfsizlik yaxlitligi darajasi (SIL) tekshiruvi yordamini taqdim etadi.

Texnik xizmat va xizmat muddati

  • Foydalanuvchi tomonidan ta’mirlanadigan qismlar yo‘q: Terminal bloki davriy tekshiruvdan tashqari maydon ta’mirini talab qilmaydi
  • Kalibrlash talab qilinmaydi: Passiv simlash interfeysi kalibrlash yoki sozlashni talab qilmaydi
  • Tekshiruv talablari: Davriy xavfsizlik tizimi sinovlari paytida terminal vint momenti va sim yaxlitligini tekshiring
  • Almashtirish mezonlari: Tekshiruv paytida jismoniy shikastlanish, korroziya yoki bo‘sh ulanishlar aniqlansa almashtiring
  • Xavfsizlik tizimi umr ko‘rish davri: Terminal bloklari odatda xavfsizlik tizimi umrining butun davri uchun xizmat qiladi (15-20 yil)

© 2025 INDUSTRIAL CONTROL HUB. Barcha huquqlar himoyalangan.
Asl Manba: https://www.indctrlhub.com
Bog'lanish: sales@indctrlhub.com | +0086 18359243191

View full details

Product Description

Emerson KJ2201X1-HA1 DeltaV SIS Simplex SLS Terminal Block - Xavfsizlik tizimlari uchun ichki xavfsiz maydon interfeysi

Emerson KJ2201X1-HA1 (12P3322X022) DeltaV SIS Simplex SLS Terminal Block xavfsizlik asbob-uskunalar tizimlarida KJ2201X1-BA1 Smart Logic Solver (SLS 1508) uchun ichki xavfsiz maydon simlarini ulashni ta'minlaydi. Xavfli hududlarga o'rnatish uchun mo'ljallangan ushbu terminal bloki xavfsizlik jihatdan muhim maydon qurilmalari bilan DeltaV SIS boshqaruvchisi o'rtasida ishonchli ulanishlarni ta'minlaydi, neft va gaz, kimyo, farmatsevtika va elektr energiyasi ishlab chiqarish korxonalarida SIL 2/3 sertifikatlangan xavfsizlik himoyasini talab qiluvchi 16 ta sozlanadigan I/O kanallarini qo'llab-quvvatlaydi.

Asosiy Texnik Xususiyatlar

  • Model raqami: KJ2201X1-HA1 (Alternativ: 12P3322X022)
  • Konfiguratsiya: Ichki xavfsiz doiralar uchun Simplex SLS terminal bloki
  • Moslik: KJ2201X1-BA1 Smart Logic Solver (SLS 1508)
  • I/O kanallari: 16 sozlanadigan kanal (DI/DO/AI HART/HART ikki holatli chiqish)
  • Joriy reytinglari: 30mA (terminal A-B), 1A (terminal A-C)
  • Ishlash harorati: -40°C dan +70°C gacha (-40°F dan 158°F gacha)
  • Saqlash harorati: -40°C dan +85°C gacha (-40°F dan 185°F gacha)
  • Himoya darajasi: O'rnatilganda IP20
  • O'rnatish: 8 kenglikdagi SIS tashuvchi ustida T-turi DIN relsi
  • Og'irligi: Taxminan 0.25 kg (0.55 lbs)

Global Xavfsizlik Sertifikatlari

Dunyo bo'ylab xavfsizlik asbob-uskunalari tizimlari va xavfli hududlarda qo'llash uchun sertifikatlangan:

  • ATEX Europe: II 3 G sertifikatlangan Zona 2 portlovchi atmosfera o'rnatmalari uchun (Nemko No. 02ATEX431U)
  • IECEx International: Xavfli joylar uchun global ichki xavfsizlik standartlariga muvofiq
  • FM/CSA Shimoliy Amerika: I sinf, 2-bo‘lim, A-D guruhlar o‘rnatishlari uchun sertifikatlangan
  • CE belgisi: Xavfsizlik va EMC direktivalari uchun Yevropa muvofiqligi
  • SIL sertifikati: Sertifikatlangan SLS bilan birga ishlatilganda SIL 2/3 xavfsizlik yaxlitligi darajasi ilovalarini qo‘llab-quvvatlaydi

Xavfsizlik Instrumentatsiyalangan Tizim Ilovalari

Favqulodda o‘chirish (ESD) tizimlari: Xavfsizlik uchun muhim o‘chirish klapanlari, favqulodda bosimni tushirish tizimlari va yong‘in hamda gaz aniqlash qurilmalarini Smart Logic Solver bilan interfeys qiling. Ichki xavfsiz dizayn portlovchi muhitni yoqolmaydigan minimal energiyali zanjirlarni ta’minlaydi, bu esa yonuvchan gazlar yoki bug‘lar mavjud bo‘lishi mumkin bo‘lgan dengiz platformalari, neftni qayta ishlash zavodlari va kimyo korxonalari uchun juda muhimdir.

Yoqilg‘i boshqaruv tizimlari (BMS): Olov detektorlari, yoqilg‘i klapan pozitsiyasi kalitlari va havo oqimi sensorlarini qozon va pech ishlarini boshqaruvchi xavfsizlik mantiqiy boshqaruvchilarga ulang. Terminal blokining 16 ta sozlanadigan I/O kanallari turli sensor turlarini, jumladan diskret kalitlar, HART qo‘llab-quvvatlangan uzatuvchilar va klapan boshqaruvi uchun ikki holatli chiqishlarni qo‘llab-quvvatlaydi, bu esa keng qamrovli yoqilg‘i xavfsizligini monitoring qilish imkonini beradi.

Yuoqori ishonchlilikdagi bosimdan himoya (HIPPS): Quvurlar bosimidan ortiqcha himoya tizimlarida ultra tez o‘chirish klapanlari va bosim uzatuvchilarini interfeys qiling. Ichki xavfsiz zanjirlar uchun 30mA tok reytingi (A-B terminallari) energiya cheklov talablariga muvofiqlikni ta’minlaydi, 1A reytingi (A-C terminallari) esa ichki xavfsizlik talab qilinmaganida yuqori quvvatli maydon qurilmalarini qo‘llab-quvvatlaydi.

Xavfsizlik o‘zaro bloklash tizimlari: Xavfli uskunalar kombinatsiyalarini yoki xavfsiz bo‘lmagan ish sharoitlarini oldini olish uchun jarayon xavfsizligi o‘zaro bloklashlarini amalga oshiring. Ruxsat beruvchi kalitlar, pozitsiya sensorlari va xavfsizlik rele chiqishlarini ulab, ishga tushirish ketma-ketligini ta’minlang, teskari aylanishni oldini oling va yuqori quvvatli uskunalarni yoqishdan oldin to‘g‘ri moslashuvni ta’minlang.

Yong‘in va gazni aniqlash: Yonuvchi gaz detektorlarini, zaharli gaz monitoringlarini va olov detektorlarini xavfsizlik o‘chirish mantiqiga integratsiya qiling. HART aloqa imkoniyati aqlli maydon qurilmalaridan ilg‘or diagnostika va ko‘p o‘zgaruvchan ma’lumotlarni taqdim etadi, bu esa sensorning eskirishi yoki kalibrlash siljishi xavfsizlik tizimi ishonchliligiga ta’sir qilishi mumkinligini erta ogohlantiradi.

Ichki xavfsiz dizayn afzalliklari

Xavfli hudud xavfsizlik tizimlarini o‘rnatishda muhim afzalliklar:

  • Energiya cheklovi: Elektr zanjirlari portlovchi muhitni yoqolmaydigan minimal elektr energiyasini hosil qiladi
  • O‘rnatishni soddalashtirish: Zona 2/Bo‘lim 2 hududlarida portlashga chidamli quvurlar yoki birikma qutilari kerak emas
  • O‘rnatish xarajatlarini kamaytirish: Ichki xavfsiz simlash qimmatbaho xavfli hudud qoplamalarini yo‘q qiladi
  • Yaxshilangan xavfsizlik: Yagona nuqtali nosozliklar bilan buzib bo‘lmaydigan passiv himoya
  • Texnik xizmat ko‘rsatish imkoniyati: Ko‘plab yurisdiktsiyalarda maydon qurilmalari issiq ish ruxsatnomalarisiz xizmat ko‘rsatish mumkin

Sozlanadigan I/O kanal imkoniyatlari

Moslashuvchan signal turlari turli xavfsizlik maydon qurilmalari talablarini qo'llab-quvvatlaydi:

Diskret kirish (DI): Xavfsizlik kalitlari holatlari, klapan chegarasi kalitlari, bosim kaliti kontaktlari va favqulodda to'xtatish tugmasi holatlarini kuzatib boring. Diskret kirishlar ochiq sxemalar xavfsiz sharoitlarni, yopiq sxemalar esa normal ishlash yoki signal holatlarini bildiradigan ishonchli monitoringni ta'minlaydi.

Diskret chiqish (DO): Xavfsizlik o'chirish klapanlari, signalizatsiya qurilmalari va ruxsat beruvchi rele bobinlarini boshqaring. Diskret chiqishlar quvvat yoki boshqaruv signali yo'qolganda maydon qurilmalarini avtomatik xavfsiz holatga o'tkazadigan de-energize-to-trip mantiqini amalga oshiradi.

Analog kirish HART: Aqlli bosim uzatkichlari, harorat sensorlari va oqim o'lchagichlarni HART raqamli aloqa bilan interfeys qiling. Asosiy jarayon o'zgaruvchilariga qo'shimcha o'lchovlar, qurilma diagnostikasi va sozlash parametrlariga HART protokoli orqali kirish, oldindan texnik xizmat ko'rsatish va ilg'or xavfsizlik mantiqini ta'minlaydi.

HART ikki holatli chiqish: HART qo'llab-quvvatlanadigan aqlli pozitsionerlar va yakuniy boshqaruv elementlarini boshqaring. Discret yoqish/o‘chirish boshqaruvini HART aloqa bilan birlashtirib, xavfsizlik o'chirish ilovalarida klapan pozitsiyasi fikr-mulohazasi, diagnostika ma'lumotlari va masofadan sozlash imkoniyatlarini taqdim etadi.

O‘rnatish talablari va eng yaxshi amaliyotlar

Ishonchli xavfsizlik tizimi ishlashi uchun muhim ko'rsatmalar:

DIN rayga o'rnatish: KJ2201X1-BA1 Smart Logic Solver bilan birga 8 kenglikdagi SIS tashuvchisidagi T-turi DIN rayga o'rnating. Terminal bloki va SLS moduli o'rtasida to'g'ri mexanik ushlash va elektr aloqasini ta'minlang. Tizimni yoqishdan oldin terminal blokining to'liq joylashganligini tekshiring, bu oraliq ulanishlarning oldini oladi.

O'z-o'zidan xavfsizlik to'siqlari: O'z-o'zidan xavfsiz bo'lmagan maydon qurilmalarini ulashda terminal blok va maydon simlari orasida sertifikatlangan o'z-o'zidan xavfsizlik to'siqlarini o'rnating. To'siqlar to'g'ri yerga ulangan va o'z-o'zidan xavfsizlik yaxlitligini saqlash uchun maxsus xavfli hudud tasnifiga mos bo'lishi kerak.

Sim o'lchami va yo'nalishi: Joriy reytinglar va kuchlanish tushishini hisoblash uchun mos sim o'lchamlaridan foydalaning. Energiya cheklovini buzishi mumkin bo'lgan induktsiyalangan kuchlanishlarni oldini olish uchun o'z-o'zidan xavfsiz simlarni o'z-o'zidan xavfsiz bo'lmagan sxemalardan alohida yo'naltiring. ATEX/IECEx o'rnatish talablariga muvofiq minimal ajratish masofalarini saqlang.

Yerga ulash va ekranlash: Terminal blok yerini xavfsizlik tizimi yer avtobusiga ulang. HART aloqa sxemalari uchun maydon qurilmasidan terminal blokgacha ekran uzluksizligini saqlang. Noto'g'ri yerga ulash analog o'lchovlarga yoki HART aloqa ishonchliligiga ta'sir qiluvchi umumiy rejim shovqinini keltirib chiqarishi mumkin.

Atrof-muhit xususiyatlari

Parametr Texnik xususiyatlar
Ishlash harorati -40°C dan +70°C gacha (-40°F dan 158°F gacha)
Saqlash harorati -40°C dan +85°C gacha (-40°F dan 185°F gacha)
Namlik Oralig‘i 5% dan 95% gacha kondensatsiyasiz
Havodagi ifloslantiruvchi moddalar ISA-S71.04-1985 G3 sinfi, konformal qoplama bilan
IP reytingi Shkafga o'rnatilganda IP20

Nima uchun Industrial Control Hub ni tanlash kerak?

Sizning haqiqiy Emerson DeltaV SIS xavfsizlik komponentlari uchun ixtisoslashgan manbaingiz:

  • ✓ To'liq ishlab chiqaruvchi izchilligi va xavfsizlik sertifikatlari bilan 100% haqiqiy OEM mahsulotlari
  • ✓ Sertifikatlangan funksional xavfsizlik muhandislari tomonidan ekspert SIS texnik qo'llab-quvvatlash
  • ✓ Hozirgi ishlab chiqarish va eski DeltaV SIS komponentlarining keng inventariyasi
  • ✓ AQSh, Buyuk Britaniya, Yevropa Ittifoqi va Osiyo-Tinch okeani bozorlariga tezkor global yetkazib berish
  • ✓ Xavfsizlik tizimi loyihalari uchun hajm chegirmalari bilan raqobatbardosh narxlar
  • ✓ Xavfsizlik qo‘llanmalari va sertifikat hujjatlarini o‘z ichiga olgan to‘liq hujjatlar

Qo‘shimcha DeltaV SIS komponentlari

Mahsulot Modeli Tavsif Havola
KJ2201X1-BA1 Logic Solver SLS 1508 Xavfsizlik boshqaruvchisi - ushbu terminal blok ulanuvchi Smart Logic Solver Mahsulotni Ko'rish
KL1604X1-BA1 Xavfsizlik tizimlarida tarmoq ulanishi uchun Xavfsizlik izolyatsiya porti (Mis) Mahsulotni Ko'rish
VE4050S2K1C0 DeltaV 8 kenglikdagi Logic Solver gorizontal ko‘taruvchi SLS va terminal bloklarini o‘rnatish uchun Mahsulotni Ko'rish

Buyurtma ma'lumotlari va tizim rejalashtirish

  • KJ2201X1-HA1 (12P3322X022): DeltaV SIS Simplex SLS Terminal Bloki (ushbu mahsulot)
  • Talab qilinadigan komponent: KJ2201X1-BA1 Smart Logic Solver (SLS 1508) - alohida sotiladi
  • Ko‘taruvchi talab qilinadi: T-turi DIN relsli 8 kenglikdagi SIS ko‘taruvchi
  • Tizim mosligi: To‘liq funksionallik uchun DeltaV v10.3 yoki undan keyingi versiyasi
  • Zaxira qismlar strategiyasi: Muhim xavfsizlik tizimlari uchun zaxira terminal bloklarini saqlang, shunda ish to‘xtashi kamayadi

Texnik Hujjatlar & Qo'llab-quvvatlash

To‘liq xavfsizlik qo‘llanmalari, o‘rnatish ko‘rsatmalari, ATEX/IECEx sertifikatlari va SIL sertifikat hujjatlari so‘rov bo‘yicha mavjud. Bizning funksional xavfsizlik muhandisligi jamoamiz murakkab DeltaV SIS loyihalari uchun tizim arxitekturasi bo‘yicha maslahat, ichki xavfsizlik hisob-kitoblari, xavfli hududlarni tasniflash bo‘yicha ko‘rsatmalar va xavfsizlik yaxlitligi darajasi (SIL) tekshiruvi yordamini taqdim etadi.

Texnik xizmat va xizmat muddati

  • Foydalanuvchi tomonidan ta’mirlanadigan qismlar yo‘q: Terminal bloki davriy tekshiruvdan tashqari maydon ta’mirini talab qilmaydi
  • Kalibrlash talab qilinmaydi: Passiv simlash interfeysi kalibrlash yoki sozlashni talab qilmaydi
  • Tekshiruv talablari: Davriy xavfsizlik tizimi sinovlari paytida terminal vint momenti va sim yaxlitligini tekshiring
  • Almashtirish mezonlari: Tekshiruv paytida jismoniy shikastlanish, korroziya yoki bo‘sh ulanishlar aniqlansa almashtiring
  • Xavfsizlik tizimi umr ko‘rish davri: Terminal bloklari odatda xavfsizlik tizimi umrining butun davri uchun xizmat qiladi (15-20 yil)

© 2025 INDUSTRIAL CONTROL HUB. Barcha huquqlar himoyalangan.
Asl Manba: https://www.indctrlhub.com
Bog'lanish: sales@indctrlhub.com | +0086 18359243191