Mahsulot ma'lumotlariga o'tish
1 ning 3

GE T35-A00HCF-F8A-H6D-M8A-PXX-U8C-W7C Transformatorni Himoya Qilish Tizimi

GE T35-A00HCF-F8A-H6D-M8A-PXX-U8C-W7C Transformatorni Himoya Qilish Tizimi

  • Manufacturer: General Electric

  • Product No.: T35-A00HCF-F8A-H6D-M8A-PXX-U8C-W7C

  • Condition:Omborda 1000 ta mavjud

  • Product Type: Transformatorni himoya qilish tizimi

  • Product Origin: USA

  • Payment: T/T, Western Union

  • Weight: 5000g

  • Shipping port: Xiamen

  • Warranty: 12 months

  • 24/7 Qo'llab-quvvatlash
  • 30-Kunlik Qaytarishlar
  • Tez yetkazib berish

Umumiy ma'lumot

  • Ishlab chiqaruvchi: General Electric
  • Model/Qism raqami: T35-A00HCF-F8A-H6D-M8A-PXX-U8C-W7C
  • Tavsif: General Electric T35-A00HCF-F8A-H6D-M8A-PXX-U8C-W7C - bu Multilin Universal Relay (UR) seriyasidan maxsus tayyorlangan Transformatorni himoya qilish tizimi bo‘lib, olti g‘ildirak/g‘ildiraklar bilan quvvat transformatorlarini tejamkor himoya qilish uchun mo‘ljallangan. Ushbu maxsus konfiguratsiya differensial, faza va yer ortiqcha oqim himoyasi uchun moslashtirilgan apparat variantlarini, shuningdek ilg‘or monitoring va aloqa imkoniyatlarini o‘z ichiga oladi. U kommunal va sanoat transformatorlari uchun ishonchli himoya va boshqaruvni ta’minlash uchun ishlab chiqilgan.

Texnik xususiyatlar

Texnik xususiyat Ma'lumotlar
Tur Transformatorni himoya qilish tizimi
Seriya Multilin Universal Relay (UR)
Buyurtma kodi taqsimoti
  • T35: Asosiy model
  • A00: Asosiy dasturiy ta'minot paketi
  • HCF: Yuqori kuchlanishli quvvat manbai (125–250 V DC, 100–240 V AC)
  • F8A: 3 ta Ethernet portli CPU (optik/tolali aralash)
  • H6D: Rangli displeyli takomillashtirilgan old panel
  • M8A: 8 ta Form-A chiqishlar, 8 ta raqamli kirishlar
  • PXX: Qo‘shimcha CT/VT moduli yo‘q
  • U8C: 8 ta RTD kirishlar
  • W7C: 6 ta CT kirishlar
Kirish/Chiqish sig‘imi 8 ta raqamli kirish, 8 ta Form-A chiqish, 8 ta RTD kirish, 6 ta CT kirish
Himoya funksiyalari Diferensial, faza ortiqcha oqim, yer ortiqcha oqim
Aloqa 3 ta Ethernet port (IEEE 1588 qo‘llab-quvvatlash), RS485
Qo‘llab-quvvatlanadigan protokollar IEC 61850, DNP 3.0, Modbus TCP, IEC 60870-5-104
Boshqaruv quvvati 125–250 V DC, 100–240 V AC, 50/60 Hz
Ishlash harorati -40°C dan +60°C gacha
Og‘irligi 5 kg (11 lbs)
Ilova Kommunal va sanoat quvvat tizimlarida transformatorni himoya qilish

 

View full details

Product Description

Umumiy ma'lumot

  • Ishlab chiqaruvchi: General Electric
  • Model/Qism raqami: T35-A00HCF-F8A-H6D-M8A-PXX-U8C-W7C
  • Tavsif: General Electric T35-A00HCF-F8A-H6D-M8A-PXX-U8C-W7C - bu Multilin Universal Relay (UR) seriyasidan maxsus tayyorlangan Transformatorni himoya qilish tizimi bo‘lib, olti g‘ildirak/g‘ildiraklar bilan quvvat transformatorlarini tejamkor himoya qilish uchun mo‘ljallangan. Ushbu maxsus konfiguratsiya differensial, faza va yer ortiqcha oqim himoyasi uchun moslashtirilgan apparat variantlarini, shuningdek ilg‘or monitoring va aloqa imkoniyatlarini o‘z ichiga oladi. U kommunal va sanoat transformatorlari uchun ishonchli himoya va boshqaruvni ta’minlash uchun ishlab chiqilgan.

Texnik xususiyatlar

Texnik xususiyat Ma'lumotlar
Tur Transformatorni himoya qilish tizimi
Seriya Multilin Universal Relay (UR)
Buyurtma kodi taqsimoti
  • T35: Asosiy model
  • A00: Asosiy dasturiy ta'minot paketi
  • HCF: Yuqori kuchlanishli quvvat manbai (125–250 V DC, 100–240 V AC)
  • F8A: 3 ta Ethernet portli CPU (optik/tolali aralash)
  • H6D: Rangli displeyli takomillashtirilgan old panel
  • M8A: 8 ta Form-A chiqishlar, 8 ta raqamli kirishlar
  • PXX: Qo‘shimcha CT/VT moduli yo‘q
  • U8C: 8 ta RTD kirishlar
  • W7C: 6 ta CT kirishlar
Kirish/Chiqish sig‘imi 8 ta raqamli kirish, 8 ta Form-A chiqish, 8 ta RTD kirish, 6 ta CT kirish
Himoya funksiyalari Diferensial, faza ortiqcha oqim, yer ortiqcha oqim
Aloqa 3 ta Ethernet port (IEEE 1588 qo‘llab-quvvatlash), RS485
Qo‘llab-quvvatlanadigan protokollar IEC 61850, DNP 3.0, Modbus TCP, IEC 60870-5-104
Boshqaruv quvvati 125–250 V DC, 100–240 V AC, 50/60 Hz
Ishlash harorati -40°C dan +60°C gacha
Og‘irligi 5 kg (11 lbs)
Ilova Kommunal va sanoat quvvat tizimlarida transformatorni himoya qilish