Mahsulot ma'lumotlariga o'tish
1 ning 6

Emerson ‎‎SE4006P2 KJ3241X1-BK1+KJ4006X1-BD1 Interfeys Karti

Emerson ‎‎SE4006P2 KJ3241X1-BK1+KJ4006X1-BD1 Interfeys Karti

  • Manufacturer: Emerson

  • Product No.: KJ3241X1-BK1+KJ4006X1-BD1

  • Condition:Omborda 1000 ta mavjud

  • Product Type: S-seriyasi seriyali interfeys kartasi, 2 portli interfeys terminal bloki bilan

  • Product Origin: USA

  • Payment: T/T, Western Union

  • Weight: 1000g

  • Shipping port: Xiamen

  • Warranty: 12 months

  • 24/7 Qo'llab-quvvatlash
  • 30-Kunlik Qaytarishlar
  • Tez yetkazib berish

📘 Mahsulotga umumiy nazar

Soha Tafsilotlar
Ishlab chiqaruvchi Emerson
Model Raqamlari SE4006P2 (KJ3241X1-BK1 va simplex terminal blokini o'z ichiga oladi), KJ3241X1-BK1 (Seriyali interfeys kartasi), KJ4006X1-BD1 (Interfeys terminal bloki)
Mahsulot Turi S-seriyasi seriyali interfeys kartasi, 2 portli interfeys terminal bloki bilan
Funktsiya DeltaV tizimini seriyali protokollarga ega qurilmalarga ulaydi (masalan, Modbus, Allen-Bradley Data Highway Plus)
Tizim mosligi DeltaV S-seriyasi boshqaruvchilari (SX, SQ), DeltaV v11.3 va undan yuqori
Kiritilgan komponentlar SE4006P2: 1 ta seriyali interfeys kartasi (KJ3241X1-BK1), 1 ta simplex terminal bloki; KJ4006X1-BD1: interfeys terminal bloki

⚙️ Uskuna Texnik Xususiyatlari

Xususiyat Texnik xususiyatlar
Seriyali portlar soni 2 (KJ3241X1-BK1 da)
Port turlari RS232, RS422/485 yarim dupleks, RS422/485 to'liq dupleks (alohida sozlanadigan)
Ma'lumot to'plamlari soni 32 (har port uchun 16)
Izolyatsiya Har bir port tizimdan va bir-biridan izolyatsiyalangan, tashqi yerga ulangan
LocalBus quvvati 12 V DC da 300 mA (KJ3241X1-BK1)
Maydon quvvati (Terminal bloki) 35 V DC da 1 A (KJ4006X1-BD1)
O'rnatish 8 kenglikdagi I/O tashuvchi har qanday slotga ulanadi
Terminal blok kalitlash O'rnatilgan I/O karta (KJ4006X1-BD1) ga muvofiq sozlanadi; aylanuvchi kalit tizimi moslikni ta'minlaydi

🔌 Aloqa spetsifikatsiyalari

Xususiyat Texnik xususiyatlar
Qo'llab-quvvatlanadigan protokollar Modbus RTU, Modbus ASCII (oldindan o'rnatilgan); maxsus drayverlar: Allen-Bradley Data Highway Plus, Mettler vazn o'lchagichi, Zaxira takomillashtirilgan Modbus, Sartorius vazn o'lchagichi
Baud Tezligi 300, 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200
Paritet Juft, Toq, Yo'q
Ma'lumot bitlari 7 yoki 8
To'xtash bitlari 1 yoki 2
Qayta urinib ko'rish soni 0–255
Xabar vaqti tugashi 100–25,500 ms (100 ms qadamlar bilan)
Uzatuvchi kechikishi 0–25,500 ms (100 ms qadamlar bilan)
Ishga tushirishda chiqishlarni yuborish DeltaV Explorerda interfeys ishga tushirilganda chiqishlarni yuborish uchun sozlanishi mumkin
Modbus funksiyalari - O'qish: Bobinlar, kirish holati, ushlab turuvchi registrlar, kirish registrlari
- Yozish: Yagona bobin, ushlab turuvchi registrlar (yagona, registr yoki ma'lumotlar to'plami rejimida)
- Eng yaxshi ishlash uchun kirish ma'lumotlari to'liq ma'lumotlar to'plami sifatida o'qiladi

🔁 Zaxira Xususiyatlari

Xususiyat Tafsilotlar
Zaxira varianti Zaxira terminal blok bilan zaxira juftligi sifatida mavjud (SE4036P2 modeli, SE4006P2 emas)
Zaxira sozlamalari DeltaV tizimi tomonidan avtomatik aniqlanadi; ikki seriyali portga ega qul qurilmasi talab qilinadi
Almashtirishni ishga tushiruvchilar Uskuna nosozligi, aloqa yo'qolishi (maydon kabeli / qul port muammolari), karta olib tashlash, boshqaruv mantiqi, Diagnostics Explorer orqali qo'lda kalit
O'tish vaqti Minimal, jarayon bezovta qilinmaydi; almashtirishda chiqishlarni qayta yuborish uchun sozlanishi mumkin
Zaxira Ishlash Zaxira karta tayyorgarlikni tasdiqlash uchun diagnostika registri uchun qul qurilmasini so'rov qiladi
Xabarnoma Operator asosiy kartadagi yaxlitlik xatosi signalizatsiyasi orqali almashtirish haqida xabardor qilinadi
Almashtirish Avtomatik ishga tushirilgan zaxira karta; xavfsiz hududlarda quvvat ostida almashtiriladi, xavfli hudud protseduralariga rioya qiling

🌡️ Atrof-muhit spetsifikatsiyalari

Parametr Texnik xususiyatlar
Ishlash harorati -40 dan 70 °C gacha (-40 dan 158 °F gacha)
Saqlash harorati -40 dan 85 °C gacha (-40 dan 185 °F gacha)
Nisbiy namlik 5 dan 95% gacha, kondensatsiyasiz
Havo orqali tarqaluvchi ifloslantiruvchilar ISA-S71.04-1985 G3 sinfi
Himoya darajasi IP20 (KJ3241X1-BK1)
Shok 10 g ½-sinus to'lqini 11 ms davomida
Vibratsiya KJ3241X1-BK1: 1 mm cho'qqidan cho'qqigacha (5–16 Hz), 0.5 g (16–150 Hz)
KJ4006X1-BD1: 1 mm cho'qqidan cho'qqigacha (2–13.2 Hz), 0.7 g (13.2–150 Hz)

✅ Sertifikatlar

Standart Tafsilotlar
CE EMC - EN 61326-1
FM (AQSh) FM 3600, FM 3611; I sinf, 2-bo'lim, A, B, C, D guruhlari, T4; I sinf, Zona 2, AEx/Ex ec IIC Gc (KJ4006X1-BD1)
cFM (Kanada) CSA C22.2 No. 213, CSA C22.2 No. 1010.1; I sinf, 2-bo'lim, A, B, C, D guruhlari, T4; FM17CA0145U (KJ4006X1-BD1)
ATEX II 3G Ex nA IIC T4 Gc (KJ3241X1-BK1, Nemko No. 11ATEX3029U); II 3G Ex ec IIC Gc (KJ4006X1-BD1, FM19ATEX0173U)
IEC-Ex II 3G Ex ec IIC Gc (KJ4006X1-BD1, IECEx FMG 19.0019U)
UKEX FM21UKEX0017U (KJ4006X1-BD1)
Dengiz IACS E10, ABS Dizayn Baholash Sertifikati, DNV Tur Tasdiqlash Sertifikati
O'rnatish bo'yicha ko'rsatmalar I sinf 2-bo'lim: 12P1293 (KJ3241X1-BK1), 12P5402 (KJ4006X1-BD1)
Zona 2: 12P2046 (KJ3241X1-BK1), 12P5404 (KJ4006X1-BD1)

🛠️ O'rnatish va Sozlash

Xususiyat Tafsilotlar
O‘rnatish 8 kenglikdagi I/O tashuvchisiga ulanadi; dipsvichlar yo'q; terminal blok faqat I/O kartasi yoki maydon simlari bo'lmasa olib tashlanadi (KJ4006X1-BD1)
Olib tashlash/Kiritish KJ3241X1-BK1: Tizim quvvati yoqilgan holda olib tashlanishi/yopishtirilishi mumkin emas
KJ4006X1-BD1: Agar I/O kartasi yoki maydon simlari ulanmagan bo'lsa, terminal blok tizim quvvati bilan qo'shilishi/olib tashlanishi mumkin
Konfiguratsiya DeltaV kontrolleri tomonidan avtomatik aniqlanadi; DeltaV Explorer orqali nuqta-va-bosish interfeysi bilan sozlanadi
Ma'lumotlarni boshqarish - Boshqaruv signallari uchun moduldan ma'lumotlar to'plami/registrga to'g'ridan-to'g'ri murojaat
- Bir DST narxida bir nechta registrlar uchun marshallashtirish moduli
- DST iste'moli bo'lmagan holda SCADA qiymatlarini ish stantsiyalari/historianlarga yuborish
Texnik xizmat ko'rsatish Foydalanuvchi tomonidan xizmat ko'rsatish uchun qismlar yo'q; kalibrlash talab qilinmaydi

📦 Buyurtma Ma'lumotlari

Tavsif Model raqami
S-seriyali seriyali interfeys kartasi, 2-portli (Simplex) SE4006P2 (KJ3241X1-BK1 va simplex terminal blokni o'z ichiga oladi)
Redundant S-seriyali seriyali interfeys kartasi, 2-portli SE4036P2 (2 ta interfeys kartasi va redundant terminal blokni o'z ichiga oladi)
Interfeys terminal bloki KJ4006X1-BD1

📝 Qo'shimcha Eslatmalar

  • Modbus qo'llab-quvvatlashi: Oldindan o'rnatilgan Modbus RTU va ASCII drayverlari; har bir port uchun master yoki slave konfiguratsiyasini qo'llab-quvvatlaydi.
  • Maxsus drayverlar: Emerson tomonidan mavjud (masalan, Allen-Bradley Data Highway Plus, Mettler/Sartorius vazn o'lchagichlari); mavjudlik uchun mahalliy savdo ofisiga murojaat qiling.
  • Redundans cheklovi: SE4006P2 simplex; redundans uchun SE4036P2 dan foydalaning. Slave qurilmalar redundant ishlash uchun ikki seriyali portni qo'llab-quvvatlashi kerak.
  • DST dan foydalanish: Ma'lumotlar to'plamlari boshqaruv modullarida to'g'ridan-to'g'ri murojaat qilinishi yoki tejamkor integratsiya uchun marshallashtirilishi mumkin; SCADA teglar DSTlarni iste'mol qilmaydi.
  • Xavfli hududda ishlash: Class I Division 2 (12P1293, 12P5402) va Zone 2 (12P2046, 12P5404) uchun maxsus o'rnatish ko'rsatmalariga rioya qiling.
  • Terminal blok mosligi: KJ4006X1-BD1 kalit pozitsiyasi to'g'ri o'rnatish uchun KJ3241X1-BK1 bilan mos kelishi kerak.
View full details

Product Description

📘 Mahsulotga umumiy nazar

Soha Tafsilotlar
Ishlab chiqaruvchi Emerson
Model Raqamlari SE4006P2 (KJ3241X1-BK1 va simplex terminal blokini o'z ichiga oladi), KJ3241X1-BK1 (Seriyali interfeys kartasi), KJ4006X1-BD1 (Interfeys terminal bloki)
Mahsulot Turi S-seriyasi seriyali interfeys kartasi, 2 portli interfeys terminal bloki bilan
Funktsiya DeltaV tizimini seriyali protokollarga ega qurilmalarga ulaydi (masalan, Modbus, Allen-Bradley Data Highway Plus)
Tizim mosligi DeltaV S-seriyasi boshqaruvchilari (SX, SQ), DeltaV v11.3 va undan yuqori
Kiritilgan komponentlar SE4006P2: 1 ta seriyali interfeys kartasi (KJ3241X1-BK1), 1 ta simplex terminal bloki; KJ4006X1-BD1: interfeys terminal bloki

⚙️ Uskuna Texnik Xususiyatlari

Xususiyat Texnik xususiyatlar
Seriyali portlar soni 2 (KJ3241X1-BK1 da)
Port turlari RS232, RS422/485 yarim dupleks, RS422/485 to'liq dupleks (alohida sozlanadigan)
Ma'lumot to'plamlari soni 32 (har port uchun 16)
Izolyatsiya Har bir port tizimdan va bir-biridan izolyatsiyalangan, tashqi yerga ulangan
LocalBus quvvati 12 V DC da 300 mA (KJ3241X1-BK1)
Maydon quvvati (Terminal bloki) 35 V DC da 1 A (KJ4006X1-BD1)
O'rnatish 8 kenglikdagi I/O tashuvchi har qanday slotga ulanadi
Terminal blok kalitlash O'rnatilgan I/O karta (KJ4006X1-BD1) ga muvofiq sozlanadi; aylanuvchi kalit tizimi moslikni ta'minlaydi

🔌 Aloqa spetsifikatsiyalari

Xususiyat Texnik xususiyatlar
Qo'llab-quvvatlanadigan protokollar Modbus RTU, Modbus ASCII (oldindan o'rnatilgan); maxsus drayverlar: Allen-Bradley Data Highway Plus, Mettler vazn o'lchagichi, Zaxira takomillashtirilgan Modbus, Sartorius vazn o'lchagichi
Baud Tezligi 300, 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200
Paritet Juft, Toq, Yo'q
Ma'lumot bitlari 7 yoki 8
To'xtash bitlari 1 yoki 2
Qayta urinib ko'rish soni 0–255
Xabar vaqti tugashi 100–25,500 ms (100 ms qadamlar bilan)
Uzatuvchi kechikishi 0–25,500 ms (100 ms qadamlar bilan)
Ishga tushirishda chiqishlarni yuborish DeltaV Explorerda interfeys ishga tushirilganda chiqishlarni yuborish uchun sozlanishi mumkin
Modbus funksiyalari - O'qish: Bobinlar, kirish holati, ushlab turuvchi registrlar, kirish registrlari
- Yozish: Yagona bobin, ushlab turuvchi registrlar (yagona, registr yoki ma'lumotlar to'plami rejimida)
- Eng yaxshi ishlash uchun kirish ma'lumotlari to'liq ma'lumotlar to'plami sifatida o'qiladi

🔁 Zaxira Xususiyatlari

Xususiyat Tafsilotlar
Zaxira varianti Zaxira terminal blok bilan zaxira juftligi sifatida mavjud (SE4036P2 modeli, SE4006P2 emas)
Zaxira sozlamalari DeltaV tizimi tomonidan avtomatik aniqlanadi; ikki seriyali portga ega qul qurilmasi talab qilinadi
Almashtirishni ishga tushiruvchilar Uskuna nosozligi, aloqa yo'qolishi (maydon kabeli / qul port muammolari), karta olib tashlash, boshqaruv mantiqi, Diagnostics Explorer orqali qo'lda kalit
O'tish vaqti Minimal, jarayon bezovta qilinmaydi; almashtirishda chiqishlarni qayta yuborish uchun sozlanishi mumkin
Zaxira Ishlash Zaxira karta tayyorgarlikni tasdiqlash uchun diagnostika registri uchun qul qurilmasini so'rov qiladi
Xabarnoma Operator asosiy kartadagi yaxlitlik xatosi signalizatsiyasi orqali almashtirish haqida xabardor qilinadi
Almashtirish Avtomatik ishga tushirilgan zaxira karta; xavfsiz hududlarda quvvat ostida almashtiriladi, xavfli hudud protseduralariga rioya qiling

🌡️ Atrof-muhit spetsifikatsiyalari

Parametr Texnik xususiyatlar
Ishlash harorati -40 dan 70 °C gacha (-40 dan 158 °F gacha)
Saqlash harorati -40 dan 85 °C gacha (-40 dan 185 °F gacha)
Nisbiy namlik 5 dan 95% gacha, kondensatsiyasiz
Havo orqali tarqaluvchi ifloslantiruvchilar ISA-S71.04-1985 G3 sinfi
Himoya darajasi IP20 (KJ3241X1-BK1)
Shok 10 g ½-sinus to'lqini 11 ms davomida
Vibratsiya KJ3241X1-BK1: 1 mm cho'qqidan cho'qqigacha (5–16 Hz), 0.5 g (16–150 Hz)
KJ4006X1-BD1: 1 mm cho'qqidan cho'qqigacha (2–13.2 Hz), 0.7 g (13.2–150 Hz)

✅ Sertifikatlar

Standart Tafsilotlar
CE EMC - EN 61326-1
FM (AQSh) FM 3600, FM 3611; I sinf, 2-bo'lim, A, B, C, D guruhlari, T4; I sinf, Zona 2, AEx/Ex ec IIC Gc (KJ4006X1-BD1)
cFM (Kanada) CSA C22.2 No. 213, CSA C22.2 No. 1010.1; I sinf, 2-bo'lim, A, B, C, D guruhlari, T4; FM17CA0145U (KJ4006X1-BD1)
ATEX II 3G Ex nA IIC T4 Gc (KJ3241X1-BK1, Nemko No. 11ATEX3029U); II 3G Ex ec IIC Gc (KJ4006X1-BD1, FM19ATEX0173U)
IEC-Ex II 3G Ex ec IIC Gc (KJ4006X1-BD1, IECEx FMG 19.0019U)
UKEX FM21UKEX0017U (KJ4006X1-BD1)
Dengiz IACS E10, ABS Dizayn Baholash Sertifikati, DNV Tur Tasdiqlash Sertifikati
O'rnatish bo'yicha ko'rsatmalar I sinf 2-bo'lim: 12P1293 (KJ3241X1-BK1), 12P5402 (KJ4006X1-BD1)
Zona 2: 12P2046 (KJ3241X1-BK1), 12P5404 (KJ4006X1-BD1)

🛠️ O'rnatish va Sozlash

Xususiyat Tafsilotlar
O‘rnatish 8 kenglikdagi I/O tashuvchisiga ulanadi; dipsvichlar yo'q; terminal blok faqat I/O kartasi yoki maydon simlari bo'lmasa olib tashlanadi (KJ4006X1-BD1)
Olib tashlash/Kiritish KJ3241X1-BK1: Tizim quvvati yoqilgan holda olib tashlanishi/yopishtirilishi mumkin emas
KJ4006X1-BD1: Agar I/O kartasi yoki maydon simlari ulanmagan bo'lsa, terminal blok tizim quvvati bilan qo'shilishi/olib tashlanishi mumkin
Konfiguratsiya DeltaV kontrolleri tomonidan avtomatik aniqlanadi; DeltaV Explorer orqali nuqta-va-bosish interfeysi bilan sozlanadi
Ma'lumotlarni boshqarish - Boshqaruv signallari uchun moduldan ma'lumotlar to'plami/registrga to'g'ridan-to'g'ri murojaat
- Bir DST narxida bir nechta registrlar uchun marshallashtirish moduli
- DST iste'moli bo'lmagan holda SCADA qiymatlarini ish stantsiyalari/historianlarga yuborish
Texnik xizmat ko'rsatish Foydalanuvchi tomonidan xizmat ko'rsatish uchun qismlar yo'q; kalibrlash talab qilinmaydi

📦 Buyurtma Ma'lumotlari

Tavsif Model raqami
S-seriyali seriyali interfeys kartasi, 2-portli (Simplex) SE4006P2 (KJ3241X1-BK1 va simplex terminal blokni o'z ichiga oladi)
Redundant S-seriyali seriyali interfeys kartasi, 2-portli SE4036P2 (2 ta interfeys kartasi va redundant terminal blokni o'z ichiga oladi)
Interfeys terminal bloki KJ4006X1-BD1

📝 Qo'shimcha Eslatmalar

  • Modbus qo'llab-quvvatlashi: Oldindan o'rnatilgan Modbus RTU va ASCII drayverlari; har bir port uchun master yoki slave konfiguratsiyasini qo'llab-quvvatlaydi.
  • Maxsus drayverlar: Emerson tomonidan mavjud (masalan, Allen-Bradley Data Highway Plus, Mettler/Sartorius vazn o'lchagichlari); mavjudlik uchun mahalliy savdo ofisiga murojaat qiling.
  • Redundans cheklovi: SE4006P2 simplex; redundans uchun SE4036P2 dan foydalaning. Slave qurilmalar redundant ishlash uchun ikki seriyali portni qo'llab-quvvatlashi kerak.
  • DST dan foydalanish: Ma'lumotlar to'plamlari boshqaruv modullarida to'g'ridan-to'g'ri murojaat qilinishi yoki tejamkor integratsiya uchun marshallashtirilishi mumkin; SCADA teglar DSTlarni iste'mol qilmaydi.
  • Xavfli hududda ishlash: Class I Division 2 (12P1293, 12P5402) va Zone 2 (12P2046, 12P5404) uchun maxsus o'rnatish ko'rsatmalariga rioya qiling.
  • Terminal blok mosligi: KJ4006X1-BD1 kalit pozitsiyasi to'g'ri o'rnatish uchun KJ3241X1-BK1 bilan mos kelishi kerak.

Download PDF file here: