GE IC200ALG430

GE IC200ALG430

  • Manufacturer: General Electric

  • Product No.: IC200ALG430

  • Condition:1000 em estoque

  • Product Type: 4-Channel Analog Input Module (RTD)

  • Product Origin: USA

  • Payment: T/T, Western Union

  • Weight: 1000g

  • Shipping port: Xiamen

  • Warranty: 12 months

  • Suporte 24 horas por dia, 7 dias por semana
  • Devoluções em 30 dias
  • Envio rápido

Product Details



Parameter Details
Manufacturer General Electric
Model/Part Number IC200ALG430
Description 4-Channel Analog Input Module (RTD)

Product Overview



Parameter Details
Part Number IC200ALG430
Product Name IC200ALG430 VersaMax 4-Channel RTD Input Module
Application High-accuracy temperature measurement using 2-wire or 3-wire RTD sensors in industrial automation, HVAC, and process control systems
Compatibility GE VersaMax I/O system; mounts on any VersaMax carrier (IC200ACCxxx); supports CPU/NIU via backplane
Function Converts four independent RTD inputs to digital values; provides 16-bit resolution, cold junction compensation, open-wire detection, and linearization

Functional Specifications



Parameter Details
Input Channels 4 differential RTD inputs (2-wire or 3-wire)
RTD Types Supported Pt100, Pt1000, Ni100, Ni120, Ni1000, Cu10, Cu50, Cu100 (α = 0.00385, 0.00392, 0.00427)
Temperature Range -200°C to +850°C (depends on RTD type)
Resolution 0.1°C (16-bit)
Accuracy ±0.5°C typical (±1.0°C max) after calibration
Excitation Current 1 mA constant current source per channel
Lead Resistance Compensation Automatic for 3-wire; manual offset for 2-wire
Update Rate 100 ms for all 4 channels
Input Impedance >10 MΩ
Open Wire Detection Yes _ detects broken or disconnected leads
Isolation 1500 V RMS field-to-backplane; 250 V RMS channel-to-channel
Common Mode Rejection >100 dB @ 50/60 Hz
Filtering Digital low-pass filter (configurable 0.1_10 Hz); 50/60 Hz notch
Linearization Automatic per IEC 60751 / DIN 43760 standards
Scaling Configurable engineering units (°C, °F, K) via PME
Diagnostics Open circuit, overrange, underrange, module fault, excitation fault
Power Supply +5 V DC @ 120 mA (from backplane)
Power Consumption 0.6 W maximum
LED Indicators Module OK (green), Fault (red), 4x Channel Active (green)
Configuration Via Proficy Machine Edition (PME); per-channel RTD type, filtering, alarms
Operating Temperature Range 0°C to +60°C
Storage Temperature Range -40°C to +85°C
Humidity 5% to 95% non-condensing
Vibration IEC 60068-2-6 (5g, 10_150 Hz)
Shock IEC 60068-2-27 (30g, 11 ms)
Mounting Snaps onto VersaMax carrier base (IC200ACCxxx)
Dimensions 4.33" x 2.60" x 1.77" (110 mm x 66 mm x 45 mm)
Weight 0.44 lb (0.20 kg)
Enclosure Rating IP20
Standards Compliance IEC 61131-2, CE, UL, CSA, Class I Division 2, ATEX Zone 2, RoHS compliant
Ver detalhes completos

Product Description

Product Details



Parameter Details
Manufacturer General Electric
Model/Part Number IC200ALG430
Description 4-Channel Analog Input Module (RTD)

Product Overview



Parameter Details
Part Number IC200ALG430
Product Name IC200ALG430 VersaMax 4-Channel RTD Input Module
Application High-accuracy temperature measurement using 2-wire or 3-wire RTD sensors in industrial automation, HVAC, and process control systems
Compatibility GE VersaMax I/O system; mounts on any VersaMax carrier (IC200ACCxxx); supports CPU/NIU via backplane
Function Converts four independent RTD inputs to digital values; provides 16-bit resolution, cold junction compensation, open-wire detection, and linearization

Functional Specifications



Parameter Details
Input Channels 4 differential RTD inputs (2-wire or 3-wire)
RTD Types Supported Pt100, Pt1000, Ni100, Ni120, Ni1000, Cu10, Cu50, Cu100 (α = 0.00385, 0.00392, 0.00427)
Temperature Range -200°C to +850°C (depends on RTD type)
Resolution 0.1°C (16-bit)
Accuracy ±0.5°C typical (±1.0°C max) after calibration
Excitation Current 1 mA constant current source per channel
Lead Resistance Compensation Automatic for 3-wire; manual offset for 2-wire
Update Rate 100 ms for all 4 channels
Input Impedance >10 MΩ
Open Wire Detection Yes _ detects broken or disconnected leads
Isolation 1500 V RMS field-to-backplane; 250 V RMS channel-to-channel
Common Mode Rejection >100 dB @ 50/60 Hz
Filtering Digital low-pass filter (configurable 0.1_10 Hz); 50/60 Hz notch
Linearization Automatic per IEC 60751 / DIN 43760 standards
Scaling Configurable engineering units (°C, °F, K) via PME
Diagnostics Open circuit, overrange, underrange, module fault, excitation fault
Power Supply +5 V DC @ 120 mA (from backplane)
Power Consumption 0.6 W maximum
LED Indicators Module OK (green), Fault (red), 4x Channel Active (green)
Configuration Via Proficy Machine Edition (PME); per-channel RTD type, filtering, alarms
Operating Temperature Range 0°C to +60°C
Storage Temperature Range -40°C to +85°C
Humidity 5% to 95% non-condensing
Vibration IEC 60068-2-6 (5g, 10_150 Hz)
Shock IEC 60068-2-27 (30g, 11 ms)
Mounting Snaps onto VersaMax carrier base (IC200ACCxxx)
Dimensions 4.33" x 2.60" x 1.77" (110 mm x 66 mm x 45 mm)
Weight 0.44 lb (0.20 kg)
Enclosure Rating IP20
Standards Compliance IEC 61131-2, CE, UL, CSA, Class I Division 2, ATEX Zone 2, RoHS compliant