Өнім туралы ақпаратқа өту
1 -ның 1

GE IC200ALG260C

GE IC200ALG260C

  • Manufacturer: General Electric

  • Product No.: IC200ALG260C

  • Condition:Қорда 1000 бар

  • Product Type: 8-Channel Analog Input Module (Voltage/Current, Revision C)

  • Product Origin: USA

  • Payment: T/T, Western Union

  • Weight: 1000g

  • Shipping port: Xiamen

  • Warranty: 12 months

  • 24/7 Қолдау
  • 30 Күндік Қайтарулар
  • Жылдам жеткізу

IC200ALG260C Parameters

Product Details



Parameter Details
Manufacturer General Electric
Model/Part Number IC200ALG260C
Description 8-Channel Analog Input Module (Voltage/Current, Revision C)

Product Overview



Parameter Details
Part Number IC200ALG260C
Product Name IC200ALG260 VersaMax 8-Channel Analog Input Module
Application Cost-effective, reliable analog signal acquisition in industrial automation, machine control, HVAC, and monitoring systems
Compatibility GE VersaMax I/O system; mounts on any VersaMax carrier (IC200ACCxxx); supports CPU/NIU via backplane; compatible with PACSystems RX3i via Profinet
Function Converts 8 single-ended analog inputs (voltage or current) to 12-bit digital values; Revision C includes faster update rate, HART pass-through support, and enhanced diagnostics

Functional Specifications



Parameter Details
Input Channels 8 single-ended analog inputs (common return)
Input Types - Voltage: 0_10 V DC, ±10 V DC - Current: 4_20 mA, 0_20 mA (jumper/software selectable per channel)
Resolution 12-bit (2.44 mV or 5 µA per LSB)
Accuracy ±0.25% of full scale at 25°C; ±0.5% over full temperature range
Update Rate 10 ms for all 8 channels (100 Hz sampling) _ improved from 15 ms in Rev B
Input Impedance >200 kΩ (voltage mode), 250 Ω ±0.1% (current mode)
Loop Power External 24 V DC required; HART-compatible loops supported
HART Pass-Through Yes _ transparent HART digital overlay (device identification and basic diagnostics) _ new in Rev C
Open Wire Detection Yes _ < 2.5 mA (current mode); configurable alarm
Overrange/Underrange ±5% beyond nominal; clamped with alarm
Isolation 1500 V RMS field-to-backplane; no channel-to-channel isolation
Common Mode Rejection >90 dB @ 50/60 Hz
Noise Rejection Configurable digital low-pass (8_512 Hz); dual 50/60 Hz notch filters
Scaling & Linearization User-defined engineering units, square root (flow), 16-point custom table
Diagnostics Open circuit, over/underrange, HART device status, module fault, backplane power monitoring
Power Supply +5 V DC @ 150 mA (from backplane)
Power Consumption 0.75 W maximum
LED Indicators Module OK (green), Fault (red), 8x Channel Active (green), HART Active (yellow)
Configuration Proficy Machine Edition (PME) 8.5+; firmware-based calibration, HART device integration
Firmware Field-upgradable via PME
Operating Temperature Range 0°C to +60°C
Storage Temperature Range -40°C to +85°C
Humidity 5% to 95% non-condensing
Vibration IEC 60068-2-6 (5g, 10_150 Hz)
Shock IEC 60068-2-27 (30g, 11 ms)
Mounting Snaps onto VersaMax carrier base (IC200ACCxxx)
Dimensions 4.33" x 2.60" x 1.77" (110 mm x 66 mm x 45 mm)
Weight 0.44 lb (0.20 kg)
Enclosure Rating IP20
Revision C Enhancements 10 ms update, HART pass-through, faster A/D, improved filtering, enhanced EMI/EMC immunity
Standards Compliance IEC 61131-2, CE, UL, CSA, Class I Division 2, ATEX Zone 2, HART 7 compatible, RoHS 2
View full details

Product Description

IC200ALG260C Parameters

Product Details



Parameter Details
Manufacturer General Electric
Model/Part Number IC200ALG260C
Description 8-Channel Analog Input Module (Voltage/Current, Revision C)

Product Overview



Parameter Details
Part Number IC200ALG260C
Product Name IC200ALG260 VersaMax 8-Channel Analog Input Module
Application Cost-effective, reliable analog signal acquisition in industrial automation, machine control, HVAC, and monitoring systems
Compatibility GE VersaMax I/O system; mounts on any VersaMax carrier (IC200ACCxxx); supports CPU/NIU via backplane; compatible with PACSystems RX3i via Profinet
Function Converts 8 single-ended analog inputs (voltage or current) to 12-bit digital values; Revision C includes faster update rate, HART pass-through support, and enhanced diagnostics

Functional Specifications



Parameter Details
Input Channels 8 single-ended analog inputs (common return)
Input Types - Voltage: 0_10 V DC, ±10 V DC - Current: 4_20 mA, 0_20 mA (jumper/software selectable per channel)
Resolution 12-bit (2.44 mV or 5 µA per LSB)
Accuracy ±0.25% of full scale at 25°C; ±0.5% over full temperature range
Update Rate 10 ms for all 8 channels (100 Hz sampling) _ improved from 15 ms in Rev B
Input Impedance >200 kΩ (voltage mode), 250 Ω ±0.1% (current mode)
Loop Power External 24 V DC required; HART-compatible loops supported
HART Pass-Through Yes _ transparent HART digital overlay (device identification and basic diagnostics) _ new in Rev C
Open Wire Detection Yes _ < 2.5 mA (current mode); configurable alarm
Overrange/Underrange ±5% beyond nominal; clamped with alarm
Isolation 1500 V RMS field-to-backplane; no channel-to-channel isolation
Common Mode Rejection >90 dB @ 50/60 Hz
Noise Rejection Configurable digital low-pass (8_512 Hz); dual 50/60 Hz notch filters
Scaling & Linearization User-defined engineering units, square root (flow), 16-point custom table
Diagnostics Open circuit, over/underrange, HART device status, module fault, backplane power monitoring
Power Supply +5 V DC @ 150 mA (from backplane)
Power Consumption 0.75 W maximum
LED Indicators Module OK (green), Fault (red), 8x Channel Active (green), HART Active (yellow)
Configuration Proficy Machine Edition (PME) 8.5+; firmware-based calibration, HART device integration
Firmware Field-upgradable via PME
Operating Temperature Range 0°C to +60°C
Storage Temperature Range -40°C to +85°C
Humidity 5% to 95% non-condensing
Vibration IEC 60068-2-6 (5g, 10_150 Hz)
Shock IEC 60068-2-27 (30g, 11 ms)
Mounting Snaps onto VersaMax carrier base (IC200ACCxxx)
Dimensions 4.33" x 2.60" x 1.77" (110 mm x 66 mm x 45 mm)
Weight 0.44 lb (0.20 kg)
Enclosure Rating IP20
Revision C Enhancements 10 ms update, HART pass-through, faster A/D, improved filtering, enhanced EMI/EMC immunity
Standards Compliance IEC 61131-2, CE, UL, CSA, Class I Division 2, ATEX Zone 2, HART 7 compatible, RoHS 2