דלג למידע על המוצר
1 של 1

GE IC200ALG230H

GE IC200ALG230H

  • Manufacturer: General Electric

  • Product No.: IC200ALG230H

  • Condition:1000 במלאי

  • Product Type: 4-Channel Analog Current Input Module

  • Product Origin: USA

  • Payment: T/T, Western Union

  • Weight: 1000g

  • Shipping port: Xiamen

  • Warranty: 12 months

  • תמיכה 24/7
  • החזרות תוך 30 יום
  • משלוח מהיר

Product Details



Parameter Details
Manufacturer General Electric
Model/Part Number IC200ALG230H
Description 4-Channel Analog Current Input Module (4_20 mA, High-Performance, Revision H)

Product Overview



Parameter Details
Part Number IC200ALG230H
Product Name IC200ALG230H VersaMax 4-Channel Analog Input Module
Application High-accuracy, high-speed measurement of 4_20 mA process signals in critical industrial automation, SCADA, and control systems
Compatibility GE VersaMax I/O system; mounts on any VersaMax carrier (IC200ACCxxx); supports CPU/NIU via backplane
Function Converts four independent 4_20 mA current loop signals to digital values; provides 16-bit resolution, HART 7 pass-through, fast update rate, and advanced diagnostics (Revision H)

Functional Specifications



Parameter Details
Input Channels 4 differential current inputs
Input Range 4_20 mA (default); 0_20 mA (configurable); ±5% overrange/underrange
Resolution 16-bit (0.61 µA per step) _ highest in ALG230 series
Accuracy ±0.05% of full scale at 25°C; ±0.1% over full temperature range
Update Rate 5 ms for all 4 channels (200 Hz sampling)
Input Impedance 250 Ω (precision shunt, 0.005% tolerance)
Loop Power External 24 V DC loop supply required; fully HART 7 compliant
HART Pass-Through Yes _ full bidirectional HART 7 digital communication (supports device configuration, diagnostics, and multivariable data)
Open Wire Detection Yes _ detects < 1.5 mA; sensor burnout detection (upscale/downscale configurable)
Overrange/Underrange Clamps at 0 mA and 24 mA; configurable alarm thresholds
Isolation 250 V RMS channel-to-channel; 1500 V RMS field-to-backplane
Common Mode Rejection > 110 dB @ 50/60 Hz
Noise Rejection Configurable digital low-pass (8_1024 Hz); dual 50/60 Hz notch filters
Scaling & Linearization User-defined engineering units, square root (flow), custom 32-point linearization table
Diagnostics Open circuit, overrange, underrange, HART device status, loop impedance monitoring, module fault, power loss
Power Supply +5 V DC @ 150 mA (from backplane)
Power Consumption 0.75 W maximum
LED Indicators Module OK (green), Fault (red), 4x Channel Active (green), HART Comm (yellow, blinking)
Configuration Via Proficy Machine Edition (PME) 9.5+; supports field calibration, HART device manager integration, firmware upgrade via USB
Firmware Field-upgradable via PME or front USB port
Operating Temperature Range 0°C to +60°C
Storage Temperature Range -40°C to +85°C
Humidity 5% to 95% non-condensing
Vibration IEC 60068-2-6 (5g, 10_150 Hz)
Shock IEC 60068-2-27 (30g, 11 ms)
Mounting Snaps onto VersaMax carrier base (IC200ACCxxx)
Dimensions 4.33" x 2.60" x 1.77" (110 mm x 66 mm x 45 mm)
Weight 0.44 lb (0.20 kg)
Enclosure Rating IP20
Revision H Enhancements 16-bit resolution, 5 ms update, full HART 7, loop impedance diagnostics, USB firmware port, enhanced EMI immunity
Standards Compliance IEC 61131-2, CE, UL, CSA, Class I Division 2, ATEX Zone 2, HART 7 Registered, RoHS 2, IEC 61000-6-2/4 (EMC)
View full details

Product Description

Product Details



Parameter Details
Manufacturer General Electric
Model/Part Number IC200ALG230H
Description 4-Channel Analog Current Input Module (4_20 mA, High-Performance, Revision H)

Product Overview



Parameter Details
Part Number IC200ALG230H
Product Name IC200ALG230H VersaMax 4-Channel Analog Input Module
Application High-accuracy, high-speed measurement of 4_20 mA process signals in critical industrial automation, SCADA, and control systems
Compatibility GE VersaMax I/O system; mounts on any VersaMax carrier (IC200ACCxxx); supports CPU/NIU via backplane
Function Converts four independent 4_20 mA current loop signals to digital values; provides 16-bit resolution, HART 7 pass-through, fast update rate, and advanced diagnostics (Revision H)

Functional Specifications



Parameter Details
Input Channels 4 differential current inputs
Input Range 4_20 mA (default); 0_20 mA (configurable); ±5% overrange/underrange
Resolution 16-bit (0.61 µA per step) _ highest in ALG230 series
Accuracy ±0.05% of full scale at 25°C; ±0.1% over full temperature range
Update Rate 5 ms for all 4 channels (200 Hz sampling)
Input Impedance 250 Ω (precision shunt, 0.005% tolerance)
Loop Power External 24 V DC loop supply required; fully HART 7 compliant
HART Pass-Through Yes _ full bidirectional HART 7 digital communication (supports device configuration, diagnostics, and multivariable data)
Open Wire Detection Yes _ detects < 1.5 mA; sensor burnout detection (upscale/downscale configurable)
Overrange/Underrange Clamps at 0 mA and 24 mA; configurable alarm thresholds
Isolation 250 V RMS channel-to-channel; 1500 V RMS field-to-backplane
Common Mode Rejection > 110 dB @ 50/60 Hz
Noise Rejection Configurable digital low-pass (8_1024 Hz); dual 50/60 Hz notch filters
Scaling & Linearization User-defined engineering units, square root (flow), custom 32-point linearization table
Diagnostics Open circuit, overrange, underrange, HART device status, loop impedance monitoring, module fault, power loss
Power Supply +5 V DC @ 150 mA (from backplane)
Power Consumption 0.75 W maximum
LED Indicators Module OK (green), Fault (red), 4x Channel Active (green), HART Comm (yellow, blinking)
Configuration Via Proficy Machine Edition (PME) 9.5+; supports field calibration, HART device manager integration, firmware upgrade via USB
Firmware Field-upgradable via PME or front USB port
Operating Temperature Range 0°C to +60°C
Storage Temperature Range -40°C to +85°C
Humidity 5% to 95% non-condensing
Vibration IEC 60068-2-6 (5g, 10_150 Hz)
Shock IEC 60068-2-27 (30g, 11 ms)
Mounting Snaps onto VersaMax carrier base (IC200ACCxxx)
Dimensions 4.33" x 2.60" x 1.77" (110 mm x 66 mm x 45 mm)
Weight 0.44 lb (0.20 kg)
Enclosure Rating IP20
Revision H Enhancements 16-bit resolution, 5 ms update, full HART 7, loop impedance diagnostics, USB firmware port, enhanced EMI immunity
Standards Compliance IEC 61131-2, CE, UL, CSA, Class I Division 2, ATEX Zone 2, HART 7 Registered, RoHS 2, IEC 61000-6-2/4 (EMC)