به اطلاعات محصول بروید
1 از 1

GE IC200ALG240-EC

GE IC200ALG240-EC

  • Manufacturer: General Electric

  • Product No.: IC200ALG240-EC

  • Condition:1000 در انبار

  • Product Type: 8-Channel Analog Input Module

  • Product Origin: USA

  • Payment: T/T, Western Union

  • Weight: 1000g

  • Shipping port: Xiamen

  • Warranty: 12 months

  • پشتیبانی 24/7
  • بازگشت 30 روزه
  • حمل و نقل سریع

Product Details



Parameter Details
Manufacturer General Electric
Model/Part Number IC200ALG240-EC
Description 8-Channel Analog Input Module (Voltage/Current, High-Density, Revision EC)

Product Overview



Parameter Details
Part Number IC200ALG240-EC
Product Name IC200ALG240 VersaMax 8-Channel Analog Input Module
Application High-density, high-accuracy analog signal acquisition in industrial automation, process control, SCADA, and safety-critical systems
Compatibility GE VersaMax I/O system; mounts on any VersaMax carrier (IC200ACCxxx); supports CPU/NIU via backplane; compatible with PACSystems RX3i, RSTi-EP, and VersaMax Micro/Nano; supports SIL 2 safety applications
Function Converts 8 fully isolated analog inputs (voltage or current) to 16-bit digital values; Revision EC includes HART 7 pass-through, process bus support (IEC 61850-9-2 LE), firmware over Ethernet, and safety certification

Functional Specifications



Parameter Details
Input Channels 8 differential, fully isolated (channel-to-channel and channel-to-ground)
Input Types - Voltage: ±50 mV, ±150 mV, 0_10 V, ±10 V - Current: 4_20 mA, 0_20 mA (software/jumper selectable per channel)
Resolution 16-bit (0.61 µA or 0.3 mV per LSB)
Accuracy ±0.05% of full scale at 25°C; ±0.1% over full temperature range
Update Rate 5 ms for all 8 channels (200 Hz sampling)
Input Impedance >1 MΩ (voltage), 250 Ω ±0.05% (current)
Loop Power External 24 V DC (19.2_28.8 V); HART 7 full compliance
HART Pass-Through Yes _ bidirectional HART 7 (multivariable, device config, diagnostics, burst mode)
Process Bus (IEC 61850-9-2 LE) Yes _ sampled values (SV) streaming over Ethernet (optional firmware mode)
Open Wire Detection Yes _ <1.5 mA (current), <5% FSR (voltage); upscale/downscale configurable
Overrange/Underrange ±10% beyond nominal; alarm thresholds per channel
Isolation 1500 V RMS field-to-backplane; 250 V RMS channel-to-channel
Common Mode Rejection >120 dB @ 50/60 Hz
Noise Rejection Configurable digital low-pass (8_2048 Hz); adaptive 50/60 Hz notch
Scaling & Linearization Engineering units, square root, 32-point custom table, RTD/TC linearization emulation
Diagnostics Open circuit, over/underrange, HART device health, loop resistance, sensor drift, self-test, watchdog
Safety Certification IEC 61508 SIL 2 capable (with certified application program)
Power Supply +5 V DC @ 140 mA, +3.3 V DC @ 110 mA (backplane)
Power Consumption 1.0 W maximum
External Power 24 V DC @ 120 mA (isolated loop supply)
Communication Ports Dual Ethernet 10/100 Mbps (RJ45, switched) _ for firmware update, config, and process bus
LED Indicators OK (green), Fault (red), 8x Active (green), HART (yellow), SV Stream (blue)
Configuration Proficy Machine Edition (PME) 9.5+, web server, USB-C front port, OPC UA server
Firmware Field-upgradable via Ethernet, USB-C, or PME
Operating Temperature Range -40°C to +70°C (extended)
Storage Temperature Range -40°C to +85°C
Humidity 5% to 95% non-condensing
Vibration IEC 60068-2-6 (10g, 10_500 Hz)
Shock IEC 60068-2-27 (50g, 11 ms)
Mounting Snaps onto VersaMax carrier base (IC200ACCxxx)
Dimensions 4.33" x 2.60" x 1.77" (110 mm x 66 mm x 45 mm)
Weight 0.46 lb (0.21 kg)
Enclosure Rating IP20
Revision EC Enhancements Extended temp, HART 7, IEC 61850-9-2 LE, dual Ethernet, SIL 2, USB-C, web config, enhanced EMC
Standards Compliance IEC 61131-2, IEC 61508 SIL 2, CE, UL, CSA, Class I Div 2, ATEX/IECEx Zone 2, HART 7, IEC 61850-9-2, RoHS 3, IEC 61000-6-2/4
مشاهده جزئیات کامل

Product Description

Product Details



Parameter Details
Manufacturer General Electric
Model/Part Number IC200ALG240-EC
Description 8-Channel Analog Input Module (Voltage/Current, High-Density, Revision EC)

Product Overview



Parameter Details
Part Number IC200ALG240-EC
Product Name IC200ALG240 VersaMax 8-Channel Analog Input Module
Application High-density, high-accuracy analog signal acquisition in industrial automation, process control, SCADA, and safety-critical systems
Compatibility GE VersaMax I/O system; mounts on any VersaMax carrier (IC200ACCxxx); supports CPU/NIU via backplane; compatible with PACSystems RX3i, RSTi-EP, and VersaMax Micro/Nano; supports SIL 2 safety applications
Function Converts 8 fully isolated analog inputs (voltage or current) to 16-bit digital values; Revision EC includes HART 7 pass-through, process bus support (IEC 61850-9-2 LE), firmware over Ethernet, and safety certification

Functional Specifications



Parameter Details
Input Channels 8 differential, fully isolated (channel-to-channel and channel-to-ground)
Input Types - Voltage: ±50 mV, ±150 mV, 0_10 V, ±10 V - Current: 4_20 mA, 0_20 mA (software/jumper selectable per channel)
Resolution 16-bit (0.61 µA or 0.3 mV per LSB)
Accuracy ±0.05% of full scale at 25°C; ±0.1% over full temperature range
Update Rate 5 ms for all 8 channels (200 Hz sampling)
Input Impedance >1 MΩ (voltage), 250 Ω ±0.05% (current)
Loop Power External 24 V DC (19.2_28.8 V); HART 7 full compliance
HART Pass-Through Yes _ bidirectional HART 7 (multivariable, device config, diagnostics, burst mode)
Process Bus (IEC 61850-9-2 LE) Yes _ sampled values (SV) streaming over Ethernet (optional firmware mode)
Open Wire Detection Yes _ <1.5 mA (current), <5% FSR (voltage); upscale/downscale configurable
Overrange/Underrange ±10% beyond nominal; alarm thresholds per channel
Isolation 1500 V RMS field-to-backplane; 250 V RMS channel-to-channel
Common Mode Rejection >120 dB @ 50/60 Hz
Noise Rejection Configurable digital low-pass (8_2048 Hz); adaptive 50/60 Hz notch
Scaling & Linearization Engineering units, square root, 32-point custom table, RTD/TC linearization emulation
Diagnostics Open circuit, over/underrange, HART device health, loop resistance, sensor drift, self-test, watchdog
Safety Certification IEC 61508 SIL 2 capable (with certified application program)
Power Supply +5 V DC @ 140 mA, +3.3 V DC @ 110 mA (backplane)
Power Consumption 1.0 W maximum
External Power 24 V DC @ 120 mA (isolated loop supply)
Communication Ports Dual Ethernet 10/100 Mbps (RJ45, switched) _ for firmware update, config, and process bus
LED Indicators OK (green), Fault (red), 8x Active (green), HART (yellow), SV Stream (blue)
Configuration Proficy Machine Edition (PME) 9.5+, web server, USB-C front port, OPC UA server
Firmware Field-upgradable via Ethernet, USB-C, or PME
Operating Temperature Range -40°C to +70°C (extended)
Storage Temperature Range -40°C to +85°C
Humidity 5% to 95% non-condensing
Vibration IEC 60068-2-6 (10g, 10_500 Hz)
Shock IEC 60068-2-27 (50g, 11 ms)
Mounting Snaps onto VersaMax carrier base (IC200ACCxxx)
Dimensions 4.33" x 2.60" x 1.77" (110 mm x 66 mm x 45 mm)
Weight 0.46 lb (0.21 kg)
Enclosure Rating IP20
Revision EC Enhancements Extended temp, HART 7, IEC 61850-9-2 LE, dual Ethernet, SIL 2, USB-C, web config, enhanced EMC
Standards Compliance IEC 61131-2, IEC 61508 SIL 2, CE, UL, CSA, Class I Div 2, ATEX/IECEx Zone 2, HART 7, IEC 61850-9-2, RoHS 3, IEC 61000-6-2/4