Gaan na produk inligting
1 van 1

GE IC200ALG264C

GE IC200ALG264C

  • Manufacturer: General Electric

  • Product No.: IC200ALG264C

  • Condition:1000 in stock

  • Product Type: 15-Channel Analog Current Input Module (4_20 mA, Revision C)

  • Product Origin: USA

  • Payment: T/T, Western Union

  • Weight: 1000g

  • Shipping port: Xiamen

  • Warranty: 12 months

  • 24/7 Ondersteuning
  • 30-dae Terugsendings
  • Vinnige Versending

Product Details



Parameter Details
Manufacturer General Electric
Model/Part Number IC200ALG264C
Description 15-Channel Analog Current Input Module (4_20 mA, Revision C)

Product Overview



Parameter Details
Part Number IC200ALG264C
Product Name IC200ALG264 VersaMax 15-Channel Analog Current Input Module
Application Ultra-high-density measurement of 4_20 mA process signals in large-scale industrial automation, SCADA, and distributed control systems
Compatibility GE VersaMax I/O system; mounts on any VersaMax carrier (IC200ACCxxx); supports CPU/NIU via backplane; compatible with PACSystems RX3i via Profinet
Function Converts fifteen independent 4_20 mA current loop signals to digital values; provides 12-bit resolution, open-wire detection, HART pass-through, fast scanning, and advanced diagnostics (Revision C)

Functional Specifications



Parameter Details
Input Channels 15 differential current inputs
Input Range 4_20 mA (default); 0_20 mA (configurable via software)
Resolution 12-bit (5 µA per step)
Accuracy ±0.25% of full scale at 25°C; ±0.5% over full temperature range
Update Rate 30 ms for all 15 channels (2 ms per channel sequential scan) _ improved from 40 ms in Rev D
Input Impedance 250 Ω (precision shunt resistor, 0.05% tolerance)
Loop Power External 24 V DC loop supply required; HART 7 fully compliant
HART Pass-Through Yes _ bidirectional HART 7 (multivariable, device config, diagnostics, burst mode)
Open Wire Detection Yes _ reports < 1.8 mA as fault; upscale/downscale configurable per channel
Overrange/Underrange Clamps at 0 mA and 24 mA; configurable alarm thresholds
Isolation 250 V RMS channel-to-channel; 1500 V RMS field-to-backplane
Common Mode Rejection > 90 dB @ 50/60 Hz
Noise Rejection Configurable digital low-pass (8_512 Hz); adaptive 50/60 Hz notch filter
Scaling & Linearization User-defined engineering units, square root (flow), 16-point custom table per channel
Diagnostics Open circuit, over/underrange, HART device health, loop resistance monitoring, module fault, backplane power loss, self-test
Power Supply +5 V DC @ 190 mA (from backplane)
Power Consumption 0.95 W maximum
LED Indicators Module OK (green), Fault (red), 15x Channel Active (green), HART Comm (yellow, blinking)
Configuration Proficy Machine Edition (PME) 9.0+; web-based configuration, HART device manager, firmware upgrade via USB
Firmware Field-upgradable via front micro-USB port or PME
Operating Temperature Range 0°C to +60°C
Storage Temperature Range -40°C to +85°C
Humidity 5% to 95% non-condensing
Vibration IEC 60068-2-6 (5g, 10_150 Hz)
Shock IEC 60068-2-27 (30g, 11 ms)
Mounting Snaps onto VersaMax carrier base (IC200ACCxxx)
Dimensions 4.33" x 2.60" x 1.77" (110 mm x 66 mm x 45 mm)
Weight 0.50 lb (0.23 kg)
Enclosure Rating IP20
Revision C Enhancements 30 ms update (25% faster), full HART 7, micro-USB port, loop resistance diagnostics, web config, improved EMC immunity
Standards Compliance IEC 61131-2, CE, UL, CSA, Class I Division 2, ATEX Zone 2, HART 7 Registered, RoHS 2, IEC 61000-6-2/4 (EMC)
View full details

Product Description

Product Details



Parameter Details
Manufacturer General Electric
Model/Part Number IC200ALG264C
Description 15-Channel Analog Current Input Module (4_20 mA, Revision C)

Product Overview



Parameter Details
Part Number IC200ALG264C
Product Name IC200ALG264 VersaMax 15-Channel Analog Current Input Module
Application Ultra-high-density measurement of 4_20 mA process signals in large-scale industrial automation, SCADA, and distributed control systems
Compatibility GE VersaMax I/O system; mounts on any VersaMax carrier (IC200ACCxxx); supports CPU/NIU via backplane; compatible with PACSystems RX3i via Profinet
Function Converts fifteen independent 4_20 mA current loop signals to digital values; provides 12-bit resolution, open-wire detection, HART pass-through, fast scanning, and advanced diagnostics (Revision C)

Functional Specifications



Parameter Details
Input Channels 15 differential current inputs
Input Range 4_20 mA (default); 0_20 mA (configurable via software)
Resolution 12-bit (5 µA per step)
Accuracy ±0.25% of full scale at 25°C; ±0.5% over full temperature range
Update Rate 30 ms for all 15 channels (2 ms per channel sequential scan) _ improved from 40 ms in Rev D
Input Impedance 250 Ω (precision shunt resistor, 0.05% tolerance)
Loop Power External 24 V DC loop supply required; HART 7 fully compliant
HART Pass-Through Yes _ bidirectional HART 7 (multivariable, device config, diagnostics, burst mode)
Open Wire Detection Yes _ reports < 1.8 mA as fault; upscale/downscale configurable per channel
Overrange/Underrange Clamps at 0 mA and 24 mA; configurable alarm thresholds
Isolation 250 V RMS channel-to-channel; 1500 V RMS field-to-backplane
Common Mode Rejection > 90 dB @ 50/60 Hz
Noise Rejection Configurable digital low-pass (8_512 Hz); adaptive 50/60 Hz notch filter
Scaling & Linearization User-defined engineering units, square root (flow), 16-point custom table per channel
Diagnostics Open circuit, over/underrange, HART device health, loop resistance monitoring, module fault, backplane power loss, self-test
Power Supply +5 V DC @ 190 mA (from backplane)
Power Consumption 0.95 W maximum
LED Indicators Module OK (green), Fault (red), 15x Channel Active (green), HART Comm (yellow, blinking)
Configuration Proficy Machine Edition (PME) 9.0+; web-based configuration, HART device manager, firmware upgrade via USB
Firmware Field-upgradable via front micro-USB port or PME
Operating Temperature Range 0°C to +60°C
Storage Temperature Range -40°C to +85°C
Humidity 5% to 95% non-condensing
Vibration IEC 60068-2-6 (5g, 10_150 Hz)
Shock IEC 60068-2-27 (30g, 11 ms)
Mounting Snaps onto VersaMax carrier base (IC200ACCxxx)
Dimensions 4.33" x 2.60" x 1.77" (110 mm x 66 mm x 45 mm)
Weight 0.50 lb (0.23 kg)
Enclosure Rating IP20
Revision C Enhancements 30 ms update (25% faster), full HART 7, micro-USB port, loop resistance diagnostics, web config, improved EMC immunity
Standards Compliance IEC 61131-2, CE, UL, CSA, Class I Division 2, ATEX Zone 2, HART 7 Registered, RoHS 2, IEC 61000-6-2/4 (EMC)